Solar Water Heater Controller main technical data:
1 Appearance of controller: see product itself ( dimension: 190mm x140mm x40mm)
2 Power supplyAC220V ±10%
3 Power consumption< 3W
4 Accuracy of temperature measuring ± 2oC
5 Range of collector temperature measuring -10 ~200 oC
6 Range of tank temperature measuring 0 ~100 oC
7 Suitable power of pump 5 pumps possible to be connected, power of each pump < 600W
8 Inputs 6 sensors,
9 2 piece Pt1000 sensor (≤500oC) for collector (silicon cable≤280oC),
10 4 pieces NTC10K, B3950 sensor (≤ 135oC) for tank, (PVC cable ≤105oC),
11 Outputs5 relays, for circulation pumps or 3-way electromagnetic valve
12 Ambient temperature -10oC ~ 50oC.
13 Water proof gradeIP40.
14 Socket choice by customer
4.1 Access main menu
4.2 Access submenu
4.3 Main menu THET Timing heating
4.4 DT Temperature difference adjusting function
4.5 TEMP Temperature main menu
4.5.1 EM Emergency collector temperature (emergency switch-off temperature of collector)
4.5.2 CMX Maximum limited collector temperature (collector cooling function)
4.5.3 CNN Low temperature protection of collector
4.5.4 CFR Frost protection of collector
4.5.5 REC Tank re-cooling function
4.5.6 SMX1 Maximum temperature of tank 1
4.5.7 SMX2 Maximum temperature of tank 2
4.5.8 SMX3 Maximum temperature of tank 3
4.5.9 MAX1 Maximum turnoff temperature (for solid fuel boiler, return heating, heat transferring between
tanks)
4.5.10 MIN1 Minimum turn-on temperature (for solid fuel boiler, return heating, heating transferring
between tanks)
4.6 FUN Auxiliary function
4.6.1 CIRC Temperature controlled hot water circulation pump
4.6.2 nMIN Circuit pump speed adjusting (RPM speed controlling)
4.6.3 DTS Standard temperature difference (for circuit pump speed adjusting)
4.6.4 RIS Increased rate (for circuit pump speed adjusting)
4.6.5 OHQM thermal energy measuring
4.6.6 FMAX Flow rate
4.6.7 MEDT Type of heat transfer liquid
4.6.8 MED% Concentration of antifreeze
4.6.9 PRIO Priority logic of tank
4.6.10 TRUN Heating loading- time
4.6.11 TSTP Heating interval- time
4.6.12 DVWG Anti-Legionella function
4.6.13 BYPR High temperature by-pass function (tank temperature automatically adjusting)
4.7 HND Manual mode
4.8 PASS Password setting
4.9 RSET Recovery factory setting
4.10 ON/OFF button
4.11 Holiday function
4.12 Manual heating
4.13 Temperature query function
5. Protection function
5.1 Memory protection
5.2 Anti-dry heating protection
5.3 Screen protection
6. Trouble shooting
6.1 Trouble protection
6.2 Trouble checking
Solar Water Heater Controller
Other Products from this Supplier
See more
Solar Water Heater Controller, solar controller, water heater controller products from this supplier.
Product Showcase[30]
Products
- Solar Collectors [96]
- Solar Tanks [35]
- All Glass Vacuum Tubes [11]
- Controllers [10]
- Heat Pipes [9]
- Solar Water Heaters [182]
- solar control [26]
- Others [6]
Company Info
Changzhou Xingwang Green Energy Co., Ltd.
[China (Mainland)]
[Verified Member]
City: Changzhou
Province/State: Jiangsu
Country/Region : China (Mainland)
Business Type:Manufacturer
Online Postings: Products